Description
The Agasthya 2013 Series Continuous Emission Monitoring System BI 7000 is designed in compliance with emission norms to measure gas pollutants emitted by various
process industry and to meet the needs of industries requiring cost effective and reliable multiple gas analyzer solutions. BI7000 is TUV certified for CE mark & Performance as per EN15267 standard.
The technology employed are of maximum reliability and accuracy to ensure high degree of performance & long life.
BI7000 is ideal solution to protect initial investment & can adapt to any process application with modular design & can house up to eight gas sensors with scalable ranges for each
gas. Manufactured for use in hostile or friendly environments the BI 7000 Continuous Emission Monitoring System maintains high levels of gas selectivity. All packed
into a robust, attractive, industrial enclosure.
Features
Tried and tested technology with proven reliability
Wide range of gas selectivity & scalable ranges available for each gas
5.7” TFT Keypad Display
The best price performance on the market – designed with user requirements foremost in mind
Isolated 4-20 mA analog output for each gas
RS 485, supports MODBUS protocol
High / Low Gas, low flow & other programmable events available
Highly efficient automatic purge & drain system
Inbuilt interface for Remote Calibration Unit
Auto & semi auto calibration facilities
Analyzer Specification:
Repeatability : 1% FS
Zero Drift : <±1% per week of Span
Span Drift : <±1% per week of Span
Response : T90 < 15 sec
Operating Temperature : 4°C to 65°C
Analog output : Isolated and linear 4-20mA analog output for each gas
Digital Communication : RS 485, Supports MODBUS Protocol
Relay Output : 2 Nos. Potential free contact for alarms
Power Supply : 110/230 VAC, 50 Hz
Programmable events for High / Low Alarms
Auto & semi auto calibration facilities
System Components
Heated Sampling Probe
Operating temperature : Max. 400ºC
Mounting : Flange Type
Max. working pressure : 6 bar
Voltage : 110/230 V, 50 /60 Hz
Heating : Self-regulating +180ºC
Ambient temperature : -20 to +80ºC
For dust concentration : Upto 5 g/m³
MOC : SS 316
Heated Sample Gas Line
Process Tube : PTFE / SS
Process Tube Size : 1/4 inch OD
Heating Element : Constant watt type
Thermal Insulation : Non – Hygroscopic Fiber Glass
Outer Sheath : Extruded UV Resistant FRLS PVC
Operating Voltage : 230 V AC
Watt Density : 45 W/m
Length : To be specified by client
Max. Operating Temperature : 200ºC
Temperature Sensor : In built RTD
Process Connection : Flanged Type
Power/Control Connection : Lead cable (3 Wire), 2 Meter for both power & control
Sample Conditioning Unit
Smart unit
Aspirator/Pump for sampling flue gas
Pre and post cooler fine filters to remove drain, dust and mist in sample gas
Auto drain and auto purging (blow back) facilities
2 way solenoid valves for switching, sampling, purging, draining and calibration
Flowmeter to regulate and monitor the flow of sample gas
Drain pump for continuous removal of condensate
NOx Converter
High NO2 conversion capability
Enclosure : 19 inch Housing
Working temperature : 400ºC
Sample gas pressure : up to 1.5 bar
Warm-up time : 30 min
Sample gas flow : up to 120 l/h
Sample gas temperature : 5 to 80ºC
Ambient temperature : 5 to 50ºC
Connection : 1/4″f NPT.
Materials : SS316, PTFE, Viton
Cabinet
Industrial Cabinet
Meets IP 54 standard
Inbuilt air conditioning system
Automatic cabinet illumination when door open
Earthing bar assembly
180 degree door opening
Standard Dimension: 1500 (H) x 600 (W) x 800(D) mm
** Purge Panel available on request for Hazardous Area.
Remote Calibration System
Panel with certified cylinders and automation for calibration
Software with User Interface for remote calibration
Compatible to interface with any Server
Server Data Connectivity to CPCB & SPCB available